Download Hybrid Series manuals for Full specs
Wiring

AWG | Max Distance (A) - Total span | Max Distance (B) - Controller to VTH | Notes | |
RVV Cable | ||||
2x0.5mm² | 20 | 180m | 100m | Max 6 Device per branch |
2x1.5mm² | 15 | 180m | 100m | Max 6 Device per branch |
RVVP Cable | ||||
2x0.5mm² | 20 | 150m | 100m | Max 6 Device per branch |
Network Cable | ||||
Cat5e Single Pair | 24 | 100m | 35m | Max 4 Device per branch |
Cat5e 'Bundle' ![]() |
24 | 200m | 100m | Max 6 Device per branch |
Telephone Wire | ||||
Telephone wire | 24 | 20m | 20m | Max 2 Device per branch |
Basic Intercom Setup
Unlike the Intercom-Ethernet counterparts (e.g INTIPRDSG2) the Intercom handset / door-stations cannot be logged into and setup via a web interface.
the units are adjusted via a series of DIP switches on the back. (Up is ‘On’ - Down is ‘Off’)

The Black on the diagram represents the switch head - not the white.
Each device has an address designated by the DIP switch's binary representation of that address
- digit placement is obviously reversed-
(The above address is '1' - not ‘128’ → as the ‘On’ switch is in the 1's place -
i.e. the address of ‘7’ is {1110 0000} as a Binary 7 is {0000 0111} )
For further information please consult the INTIPRDS-H manual above - pg15
Section 6.1: DIP Switch Introduction
the INTRDS-H → address pins 1-2-3-4
the INTIPMON-H → address pins 1-2-3-4-5-6-7-8
the other pins are used for adjusting settings
Setup 1 VTO, 1 VTH

Hand-station addresses
Regarding the INTIPRDS-H the door station can only call out to the handset address ‘1’
so setting the hand-stations to other addresses won't yield results in a basic setup.
Setup 2+ VTO, 2+ VTH

!!! Handset addresses !!!
Regarding the INTIPRDS-H the door station can only call out to the handset address ‘1’
so setting the hand-stations to other addresses won't yield results in a basic setup.
You need to set all but one handset to extension as there will be a a main unit address conflict otherwise.
!!! Door-station Addresses !!!
Door-stations need individual addresses
Setup Door station on Handset
After the wiring connection have been made you will need to setup the door station addresses on the monitor/handset
Select Monitor

Select Monitor > Add:
To add new VTOs. Enter the ID number and the name of the VTO, and then tap OK.

Do this for all Door station Addresses
Intercom unlock duration
The INTRDS-H intercom unlocking duration is set via Door station's DIP Switches on back
on Pins 5 & 6

Setup Cameras
A feature of these intercoms is the use viewing cameras on the monitors
as these are Hybrid intercoms the handset units provide the user 2 available Analogue/HDCVI pins for the user's viewing experience.
By the activation of DIP13 the CVI input enables the analogue camera inputs on the handsets.

The Intercoms once fitted with a Coax-to-2 wire adapter can easily attach the camera's BNC/coax connector
Analogue camera ground is shared between both cameras


Monitor Screen

- Main VTH If there is no icon, this is a sub VTH.
- Call Call other VTOs, or DMSS users.
- Monitor Monitor VTOs and HDCVI cameras.
- DND Enable to not receive any calls.
- Icons to Display status
- Info to display alerts & messages
- Time/Date
- Arm/Disarm
- Settings
Procedure to view from Monitor/Hand-station
- Step 1 Select Monitor > Camera.
- Step 2 Tap
to monitor the camera you selected.

Setup DMSS
In order to Setup DMSS on the Hybrid intercoms with will need to pair the DMSS app to the Handsets
but the DMSS app requires a DMSS account, if you don't have one you will need to create one.

Procedure
![]() |
|
![]() |
|
![]() |
|
![]() |
|
- Test the DMSS App
To call DMSS, you must have added the VTH to the DMSS account - (1. to 8.)
Procedure
Step 1 Select Call > DMSS.

Step 2 Tap to call the DMSS app account that the VTH has bonded with.