Cornick Help Center

    SSL-B50MC Remote Programming for Light Use

    October 15th, 2021

    Below are the default setting that should be loaded for the SSL-B50MC which is a 12V System.

    Note that while the trigger and timing settings here can be changed, however the settings shown in bold are critical to the charging of the battery and should not be altered:

    Bat Type: Li_Po

    BoostCharge: 14.4

    Voltage Low: 10.5

    Recover Vol: 12

    PowerSaving: OFF

    TurnOnPVVol: 5V

    Output Cur: 1550ma

    DriveMode: Sense

    Light Delay: 30s

    First Time: 6.00 HR

    Light Ratio: 100%

    Idle Ratio: 30%

    Second Time: 4.00 HR

    Light Ratio: 60%

    Idle Ratio: 20%

    Third Time: 8.00 HR

    Light Ratio: 100%

    Idle Ratio: 30%

    FourthTime: 0 HR

    Light Ratio: 0%

    Idle Ration: 0%

    Fifth Time: 0 HR

    Light Ratio: 0%

    Idle Ratio: 0%

    MorningLight: Off

    Was this article helpful?