Cornick Help Center

    SSL-B60MC Remote Programming - Solar Light Use

    October 13th, 2021

    Below are the setting required for the SSL-B60MC which is a 24V System.

    Note that while the trigger and timing settings here can be changed to turn on the light,  settings shown in bold are critical to the charging of the battery and should not be altered:

    Bat Type: Li_Po

    BoostCharge: 28.8

    Voltage Low: 21

    Recover Vol: 24

    PowerSaving: ON

    StartSaving: 24.80V

    SuperSaving: 24.00V

    TurnOnPVVol: 6V

    Output Cur: 1800ma

    DriveMode: Sense

    Light Delay: 30s

    First Time: 6.00 HR

    LightRatio: 100%

    Idle Ratio: 30%

    Second Time: 4.00 HR

    LightRatio: 60%

    Idle Ratio: 20%

    Third Time: 8.00 HR

    LightRatio: 100%

    Idle Ratio: 30%

    FourthTime: 0 HR

    LightRatio: 0%

    Idle Ration: 0%

    Fifth Time: 0 HR

    Light Ratio: 0%

    LightRatio: 0%

    MorningLight: Off